Symptom Likely cause Fix
invalid choice 'eventsv2' / eventbridgev2 CLI < 2.37.3 (or still on 2.36.x) Upgrade AWS CLI to ≥ 2.37.3; confirm aws eventsv2 help
Refusing to mutate AWS Gate unset export EB_ENHANCED_ALLOW_AWS=1
RAM OperationNotPermittedException Org-wide RAM sharing not enabled One-time on the management account (out of lab scope): aws ram enable-sharing-with-aws-organization — then recreate the lab→dev share
Subscriber created but verify get-item empty Filter mismatch, share not visible, or eval crashing Confirm bus ARN via list-event-buses in both profiles; check health-eval logs; republish
Bus missing from list-event-buses in dev RAM share not associated Check ram get-resource-share-associations (lab) and ram list-resources --resource-owner OTHER-ACCOUNTS (dev)
CloudWatch Datapoints: [] on EventsV2 Lag, wrong dim, or empty window Wait; confirm BUS_DIM / SUB_DIM are name/id suffixes; widen --start-time
Verify fails DLQ not empty Target invoke / handler errors Inspect health-alerts-dlq and /aws/lambda/health-eval
put-events PUBLISHED but no Dynamo row Subscriber after events / LATEST Create Subscriber first; republish
Stale alert wins Ordering / ts Ensure EventGroupId set; check source_event_ts no-op path in logs
Bridge invoke fails Missing eventbridgev2 model / IAM Zip must include bridge/data/ (see Deploy lab); check PutEvents on bus ARN and /aws/lambda/eb-bridge
Device event never hits bus Rule not wired / filter mismatch Check telemetry first (iot_talk_telemetry / iot_talk_fleet_telemetry) — that is the busy path; each must list eb-bridge; Subscriber filter source=iot.lab
IoT rule broken after teardown Bridge deleted before rules restored Re-run teardown-lab.sh (restores ingest-only) or set each events/telemetry rule action to iot-talk-ingest only
Bus delete fails Subscriber still attached Tear down dev first; wait until Subscriber is gone